Xmtg-2000 Temperature Controller Manual Pdf ✮ | FAST |
Disclaimer: This information is for informational purposes. Always consult the specific wiring diagram printed on your device.
Press the key briefly. The SV display digits will begin flashing. Use the ◀ key to select the digit you wish to modify.
Press the button briefly. The SV display digits will begin flashing. xmtg-2000 temperature controller manual pdf
Terminals for Relay, SSR (Solid State Relay), or analog output. Alarm outputs: Terminals for high/low limit relay triggers. Panel Description
Searching for the can be frustrating. Many links lead to sketchy download sites or generic manuals that don't match your specific model revision. This article serves as your ultimate resource—not only helping you locate the genuine PDF but also summarizing its most critical sections so you can get your system running immediately. Disclaimer: This information is for informational purposes
| Parameter | Value / Details | | ----------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------- | | | XMTG-2000 series (e.g., XMTG-2001, XMTG-2002, etc.) | | Display Type | 4-digit LED / LCD | | Display Range | -1999 to 9999 | | Measurement Accuracy | ≤ 1.0% FS ± 1 digit (0.5% FS for some models) | | Input Types | Thermocouple (K, J, E, S, B, T), RTD (Pt100, Cu50) | | Control Mode | PID (Proportional-Integral-Derivative) | | Output Options | Relay (3A @ 220V AC resistive), SSR (0-12V DC), 4-20mA, 1-5V, etc. | | Power Supply | 90-242V AC, 50/60 Hz | | Power Consumption | < 3W | | Panel Cutout Dimension | 45 x 45 mm | | External Dimensions (WxHxD) | 48 x 48 x 110 mm | | Weight | Approximately 0.3 kg | | Operating Temperature | 0 to 50℃ | | Relative Humidity | < 85% RH (non-condensing) |
The XMTG-2000 is a microprocessor-based controller. While it looks simple—usually featuring a digital display and four buttons—the logic behind it is complex. Without the manual, you risk: The SV display digits will begin flashing
| Parameter Code | Description | Typical Setting | | -------------- | -------------------------------------------------- | ------------------------------------------------- | | | Proportional Band (0-9999) | Set based on PID autotuning results | | I | Integral Time (0-3600 seconds) | Set based on PID autotuning results | | D | Derivative Time (0-3600 seconds) | Set based on PID autotuning results | | AL1 | Alarm 1 value | Sets the high alarm threshold | | AL2 | Alarm 2 value | Sets the low alarm threshold | | SN | Input sensor selection | Select your sensor type: 'K', 'PT1', 'Pt100', etc. | | DP | Decimal point position | Set if displaying non-integer values | | At | PID Autotuning Enable/Disable | Set to '1' or 'ON' to start autotuning |
Relay outputs are often found on terminals 6, 7, and 8 .
To help finalize your documentation setup, please let me know:
Specific terminals for thermocouples or RTD wires.